美NORTH STAR 高壓探頭

Voltage Probe Manual and Data

North Star Research Corporation

 

Standard Voltage Probe Data

High Voltage Probes Up to 400 kV

 

High Voltage Probes

High voltage measurements have a variety of different requirements, and our PVM series and VD series probes are designed for most of these requirements. The PVM probes are designed for wide bandwidth and ease of portability where a variety of measurements must be made. The VD series probes are designed for use at higher voltage ranges, and where physical stability is required.

Specialty Probes PVM series probes with PVM-5 on top and PVM-10 on the bottom

The design of the probes is unique. The probe comes fully adjusted without any requirement to further adjust the probe in the field. Stray capacitances internal to the probe are factory calibrated. Stray capacitances due to proximity effects are minimied by the unique conductor placement.

Low temperature and voltage coefficient resistors and capacitors are used throughout the probe to provide maximum measurement accuracy. The probe has a rugged nylon housing, and it is filled with dielectric oil for maximum high voltage stability.

Our PVM Series probes our available with either 1000:1 or 2000:1 calibration factors at the time of order.

Voltage Probe Specifications

PVM Series Portable High Voltage Probes to 60 kV DC

PVM series high voltage probes are designed for general use, and for exceptional high frequency response. The probes have applications ranging from automotive ignition to excimer laser system measurement to EMI measurement. They are factory calibrated, and they do not require adjustment. In general the probes are for use with 1 Megohm oscilloscopes, but we also offer an optional switch which can compensate for various measurement instruments such as 10 Megohm meters as well. These units are intended for a wide range of applications where portability and ease of use are essential.

 

Model Number

PVM-1

PVM-2

PVM-3

PVM-4

PVM-5

PVM-6

PVM-11 (PVM-10)

PVM-12

Max DC/Pulsed V (kV)

40/60

40/60

40/60

40/60

60/100

60/100

10/12

25/30

Max Frequency (Mh.)

80

80

40

110

80

80

50

80

Cable Impedance (ohms)

50

50

50

93

50

50

50

50

DC - 2 H.accuracy

<0.1%

<0.1%

<0.1%

<0.1%

<0.1%

<0.1%

<0.1%

<0.1%

2 H. - 200 H. accuracy

<1 %

<1. %

<2. %

<1. %

<1 %

<1 %

<1.5 %

<1.5 %

200 H. - 5 Mh. accuracy

<1.5%

<1.5%

<3%

<1.5%

<1.5%

<1.5%

<2.%

<2.%

> 5 Mh. Accuracy

<3%

<3%

<4%

<5%

<3%

<4%

<4%

<4%

Input R/C (Megohm/pf)

400/13

400/13

400/10

400/10

400/12

400/12

100(50)/15

300/7

Cable Length (ft./m)

15/4.5

30/9

100/30

15/4.5

15/4.5

30/9

15/4.5

15/4.5

Standard Divider Ratio

1000:1

1000:1

10,000:1

1000:1

1000:1

1000:1

1000:1 (100:1)

1000:1

Length (inches/cm.)

19/47

19/47

19/47

19/47

19/47

19/47

7/18

9/23

*美NORTH STAR 高壓探頭

Add -2 to any PVM-1 - PVM-6 or PVM-12 part number for 2000:1 ratio

VD Series High Voltage Probes 60 to 300 kV DC

Specialty Probes

VD series high voltage probes are floor standing high voltage probes which are designed for rugged day in - day out use. They are used in a wide range of applications ranging from evision tube manufacturing to radar to advanced particle accelerator applications. Resistors with an extremely low voltage coefficient of resistance are used, and all capacitors are temperature, frequency, and voltage stabilied for the best possible performance. The probes all have field defining toroids as a standard item in order to minimie the proximity effect (stray *美NORTH STAR 高壓探頭capacitance) and maximie the reproducibility of the measurement. The high and low frequency calibrations are carefully matched before shipment. Very high frequency cable effects are also carefully compensated so accurate measurements can be made even when the cable length exceeds the pulse duration. No adjustments are necessary once the probes have been factory calibrated.

Model Number

VD-60

VD-100

VD-150

VD-200

VD-300

VD-400

Max DC/Pulsed V (kV)

60/120

100/180

150/240

200/300

300/420

400/550

Max Frequency (Mh.)

20

20

20

16

12

8

Cable Length (ft.)

30

30

30

30

30

30

DC accuracy

<0.1%

<0.1%

<0.1%

<0.1%

<0.1%

<0.1%

10 H. - 1 Mh. Accuracy

1 %

1 %

1 %

2 %

2.5 %

3 %

>1 Mh Accuracy

3 %

3 %

3 %

3 %

4 %

4 %

Resistance (Megohms)

800

1600

2000

2800

4500

7000

Height (inches/cm.)

20/50

24/60

30/75

40/99

54/135

72/180

Diameter (in/cm.)

11/28

11/28

12/29

16/40

24/61

24/61

Capacitance (approx. pf)

27

25

27

24

20

16

Base Diameter(in/cm.)

10/25

10/25

12/30

20/50

30/76*

30/76

Standard Divider Ratio

10,000:1

10,000:1

10,000:1

10,000:1

10,000:1

10,000:1

 

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細(xì)地址:

  • 補(bǔ)充說明:

  • 驗(yàn)證碼:

    請(qǐng)輸入計(jì)算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7
北京志鴻恒拓科技有限公司

北京志鴻恒拓科技有限公司

地址:北京市朝陽區(qū)建國(guó)路88號(hào)soho現(xiàn)代城

© 2024 版權(quán)所有:北京志鴻恒拓科技有限公司  備案號(hào):京ICP備16029562號(hào)-5  總訪問量:574091  sitemap.xml  技術(shù)支持:化工儀器網(wǎng)  管理登陸

最近中文字幕在线中文一页 | av国産精品毛片一区二区小说| 大肉蒂被嘬的好爽H娇门吟 | chinese真实incest农村寡妇| 亚洲和欧洲一码二码区别在| 色噜噜综合亚洲AV中文无码 | 兰花草在线影院| 被小男滋润的熟妇| 妈妈的朋友电影| 日本无码色情三级播放| 国产精品国色综合久久| 两个8丫头稚嫩紧窄| 70歳の熟女セックス合集 | 被学长抱进小树林c个爽| 久久综合亚洲欧美成人| 国产成人无码a区在线观看视频| 亚洲gv猛男gv无码男同网站 | 国产av片在线| 久久久久亚洲AV片无码下载蜜桃| 杨门十二寡妇肉床艳史电影| 欧美熟妇av欧差aa片| 小莹乳液汁水停电了还能用吗| 成人性生交大片免费看中国| 亚洲理论电影在线观看| 扒开粉嫩小泬白浆20p| 极品新婚夜少妇真紧| 大陆熟妇丰满多毛XXXX| 欧美日韩免费观看在线影片| 永久免费的啪啪网站免费观看浪潮| a级春药情欲片在线观看bdo| 天天躁日日躁狠狠躁av中文| 国产精品国产三级国快看| 欧美vivo18| 人妻丝袜无码国产一区| 日本三级在线播放线观看| 女人下面又黑又大| 被学长抱进小树林c个爽| 亚洲av无码一区二区乱子伦| 色视频无码专区在线观看| 国产精品后入内射日本在线观看| 无码免费一区二区三区免费播放|